Data center ductwork.
Protected for the next stage.

Commercial HVAC duct fabrication with protected ends, project-specific construction and delivery coordinated around your installation sequence. We manufacture. You install.

Protection matters

Dust protection starts at both ends.

We specialize in commercial ductwork supplied fully assembled with blue wrap on both ends to help keep dust and dirt out during handling and delivery. Protected openings are especially useful when duct is delivered before the receiving area is ready for installation.

Send the project's cleanliness, packaging and inspection requirements with the drawings. We confirm the required protection and acceptance criteria before fabrication. End wrapping is a protective measure, not a claim of cleanroom certification, sterile handling or a dust-free finished system.

Keep end protection in place until installation, inspect it on receipt, and report damaged or open wrapping before the shipment is put into storage.

Fabricated DuctAxis ductwork with blue-wrap end protection
DuctAxis fabrication and blue-wrap protection. Project-specific packaging is confirmed with the order.

A fabrication package built around the specification.

Duct and fittings

Rectangular and spiral duct, transitions, offsets, plenums and equipment connections. Supply dimensions, material, gauge and connection details together so components are reviewed as a package.

Browse duct products →

Lined and double-wall

Identify the specified liner or insulation, its thickness and any solid or perforated inner wall. State whether drawing dimensions are clear inside dimensions or outside dimensions.

Double-wall construction →

Specialty construction

Include stainless grade, finish, welding requirements and any pressure, leakage or testing provisions. Required project approvals and testing must be reviewed, not assumed from a product name.

Stainless steel duct →

What to send for a data center duct quote

  1. Current mechanical drawings and specifications. Include revisions, duct schedules, equipment interfaces and the division of scope between the fabricator and installing contractor.
  2. Construction and performance requirements. Identify pressure class, material, gauge, connections, insulation, acoustical requirements and any specified inspection or leakage tests.
  3. Cleanliness and end protection requirements. Include handling, packaging, storage, inspection and documentation provisions from the project specification.
  4. Release sequence and identification. Show building, floor, zone, system or phase references. Separate the bid deadline from the required ship and receiving dates.
  5. Receiving arrangements. Provide the delivery address, site contact, dock or unloading equipment, appointment requirements and restrictions affecting an LTL shipment.

Plan the freight with the fabrication.

LTL shipping is available for projects across our expanded service area. Freight cost, packaging, shipment configuration and transit arrangements are confirmed for the specific order. Oversized duct or time-sensitive releases may need a different shipping arrangement.

Tell us how much duct can be received and stored at one time. We review release requirements with the fabrication scope so quoting does not assume a single delivery when the project needs multiple stages.

Explore delivery coverage →

Fabrication only. Clear responsibilities.

DuctAxis supplies the fabricated ductwork. The installing contractor and project team remain responsible for installation, site storage, commissioning and acceptance of the installed system. Any shop testing, documentation or special cleanliness protocol must be expressly included in the agreed scope.

Request a free estimate